Efficient Networks S120 manual Edigital digital inputs, Sync

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 387
Image 387

Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Table 10-24 Description of CU_ZSW (status word for Control Unit)

Bit

Meaning

 

Remarks

BICO

0...2

Reserved

3

Fault active

1

Fault active

BO: r2139.3

 

 

0

No fault present

 

4...6

Reserved

7

Alarm present

1

Alarm present

BO: 2139.7

 

 

0

No alarm present

 

8

SYNC

BO: r0899.8

9...11

Reserved

12

Drive unit sign-of-life bit 0

Slave sign of life

Implicitly

13

Drive unit sign-of-life bit 1

 

interconnec-

 

ted

14

Drive unit sign-of-life bit 2

 

 

 

15

Drive unit sign-of-life bit 3

 

 

E_DIGITAL (digital inputs)

See function diagram [2459].

Table 10-25 Description of E_DIGITAL (digital inputs)

Bit

Meaning

 

Remarks

BICO

0

Digital input/output 8

DI/DO 8 on the Control Unit must be parameterized as an input

BO: p0722.8

 

(DI/DO = 8)

 

(p0728.8 = 0).

 

1

Digital input/output 9

DI/DO 9 on the Control Unit must be parameterized as an input

BO: p0722.9

 

(DI/DO = 9)

 

(p0728.9 = 0).

 

2

Digital input/output 10

DI/DO 10 on the Control Unit must be parameterized as an input

BO:

 

(DI/DO = 10)

 

(p0728.10 = 0).

p0722.10

3

Digital input/output 11

DI/DO 11 on the Control Unit must be parameterized as an input

BO:

 

(DI/DO = 11)

 

(p0728.11 = 0).

p0722.11

4

Digital input/output 12

DI/DO 12 on the Control Unit must be parameterized as an input

BO:

 

(DI/DO = 12)

 

(p0728.12 = 0).

p0722.12

5

Digital input/output 13

DI/DO 13 on the Control Unit must be parameterized as an input

BO:

 

(DI/DO = 13)

 

(p0728.13 = 0).

p0722.13

6

Digital input/output 14

DI/DO 14 on the Control Unit must be parameterized as an input

BO:

 

(DI/DO = 14)

 

(p0728.14 = 0).

p0722.14

7

Digital input/output 15

DI/DO 15 on the Control Unit must be parameterized as an input

BO:

 

(DI/DO = 15)

 

(p0728.15 = 0).

p0722.15

8

Digital input 0 (DI 0)

Digital input DI 0 on the Control Unit

BO: r0722.0

9

Digital input 1 (DI 1)

Digital input DI 1 on the Control Unit

BO: r0722.1

10

Digital input 2 (DI 2)

Digital input DI 2 on the Control Unit

BO: r0722.2

11

Digital input 3 (DI 3)

Digital input DI 3 on the Control Unit

BO: r0722.3

12

Digital input 4 (DI 4)

Digital input DI 4 on the Control Unit

BO: r0722.4

13

Digital input 5 (DI 5)

Digital input DI 5 on the Control Unit

BO: r0722.5

14

Digital input 6 (DI 6)

Digital input DI 6 on the Control Unit

BO: r0722.6

15

Digital input 7 (DI 7)

Digital input DI 7 on the Control Unit

BO: r0722.7

Drive Functions

387

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 387
Image 387
Efficient Networks S120 manual Edigital digital inputs, Sync