Vector control

4.12 Motor data identification and rotating measurement

.S

S

S[S

.S3URSRUWLRQDOJDLQ

LT7RUTXHJHQHUDWLQJFXUUHQW

S S LT

Figure 4-16 Current controller adaptation for p0393 < 1, with p0391 < p0392

or (e.g for the ASM) when the iq points are swapped

Kp

.S3URSRUWLRQDOJDLQ

 

 

LT7RUTXHJHQHUDWLQJFXUUHQW

p1715 x p0393

p1715

p0392

p0391

iq

Figure 4-17 Current controller adaptation with swapped iq interpolation points for p0393 > 1, with p0392 < p0391

Function diagrams (see SINAMICS S List Manual)

6710 Current setpoint filters

6714 Iq and Id controller

Overview of key parameters (see SINAMICS S List Manual)

p0391 Current controller adaptation starting point KP

p0392 Current controller adaptation starting point KP adapted

p0393 Current controller adaptation P gain scaling

p1703 Isq current controller pre-control scaling

p1715 Current controller P gain

p1717 Current controller integral time

4.12Motor data identification and rotating measurement

Description

Two motor identification options, which are based on each other, are available:

Motor identification with p1910 (standstill measurement)

Rotating measurement with p1960

138

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 138
Image 138