Applications 11.3 Motor changeover

3.Open the motor contactor:

Motor contactor 1 is opened r0830 = 0 and the status bit "Motor data set changeover active" (r0835.0) is set.

4.Change over the drive data set:

The requested data set is activated (r0051 = requested data set).

5.Energize the motor contactor:

After the feedback signal (motor contactor opened) for motor contactor 1, the appropriate bit of r0830 is set and motor contactor 2 is energized.

6.Enable the pulses:

After the feedback signal (motor contactor closed) for motor contactor 2, the bit "motor changeover active" (r0835.0) is reset and the pulses are enabled. The switchover is complete.

11.3.4Integration

The motor switchover function is integrated in the system as follows.

Function diagrams (see SINAMICS S List Manual)

8565 Drive Data Sets (DDS)

8570 Encoder Data Sets (EDS)

8575 Motor Data Sets (MDS)

Overview of key parameters (see SINAMICS S List Manual)

r0051 Drive data set (DDS) effective

p0130 Motor data sets (MDS) number

p0140 Encoder data sets (EDS) number

p0180 Drive data sets (DDS) number

p0186 Motor data sets (MDS) number

p0187 Encoder 1 encoder data

p0820 BI: Drive data set selection DDS, bit 0

...

p0824 BI: Drive data set selection DDS, bit 4

p0826 Motor switchover motor number

p0827 Motor switchover status bit number

p0828 BI: Motor switchover feedback

p0830 CO/BO: Motor switchover status

p0831 BI: Motor switchover contactor feedback

p0833 Data set changeover configuration