Commissioning the pump if it is installed out of water:
4 | 7 | |
8 | ||
|
5 |
3 |
6 |
If the pump is installed out of water, the filter housing 4 must be taken off.
1.Pull off the filter housing 4.
2.Turn the pump inlet 5 anticlockwise and pull it vertically off the motor housing 6 (bayonet socket).
3.Depending on the pumping application, the pump inlet can be
rotated in 90° steps. Twist the pump inlet 5 accordingly, again press it vertically on to motor housing 6 and tighten it clock- wise (see 5. Cleaning).
4.Screw stepped nipples 7 on to the pump inlet 5 and pump outlet 8.
5.Connect the pump inlet 5 to the water reservoir with a hose (1/2" or 3/4" ). The level in the water reservoir must be higher than the pump inlet 5.
6.Connect the pump outlet 8 to the spring / gargoyle with a hose (1/2" or 3/4" ).
7.Fill the hose to the pump inlet 5 with water.
8.Insert the pump plug into a mains socket.
Caution: The pump will start immediately.
9.Use the flow control 3 to set the desired water flow for the spring.
GB