| Cleaning the RP 600: |
GB | B |
|
|
1
2
4 | A |
|
5 | 6 |
1.Pull off the fountain socket 1 and nozzle tube 2.
2.Unscrew the fountain insert B and clean it.
3.Remove the filter housing 4 from the motor housing 6, and clean it.
4.Turn the pump inlet 5 anticlockwise and pull it vertically off the motor housing 6 (bayonet socket).
5.Take the impeller A out of the motor housing 6 and clean it.
6.Push the cleaned impeller A back into the motor housing 6.
7.Push the pump inlet 5 vertically onto the motor housing 6 and tighten it clockwise. (If the pump is to suck from underneath, the thread must face downwards).
8.Push the filter housing 4 back on to the motor housing 6.
9.Screw the desired fountain insert B into the fountain socket 1.
10.Plug the fountain socket 1 and nozzle tube 2 back into place.
22