Vector control 4.15 Instructions for commissioning permanent-magnet synchronous motors

Temperature protection can be implemented using a temperature sensor (KTY/PTC). In order to achieve a high torque accuracy, we recommend that a KTY temperature sensor is used.

Table 4-5

Motor data

 

 

 

 

 

Parameter

 

Description

Remark

p0304

 

Rated motor voltage

If this value is not known, a "0" can also be

 

 

 

entered. Using this value, the stator leakage

 

 

 

inductance can be more precisely calculated

 

 

 

(p0356, p0357).

p0305

 

Rated motor current

-

p0307

 

Rated motor power

-

p0310

 

Rated motor frequency

-

p0311

 

Rated motor speed

-

If the torque constant kT is not stamped on the rating plate or specified in the data sheet, you can calculate this value from the rated motor data or from the stall current Io and stall torque Mo as follows:

N7QRP

 

30RWQRP

 

 

 

˭ ຘ

PLQ

ຘ Q

ຘ ,

 

 

 

 

 

0RWQRP

 

 

 

V

 

QRP

 

 

 

 

 

 

 

 

 

Table 4-6

Optional data

 

 

 

 

 

 

 

 

 

Parameter

 

 

 

Description

Remark

p0314

 

 

 

 

Motor pole pair number

-

p0316

 

 

 

 

Motor torque constant

-

p0320

 

 

 

 

Motor rated magnetization

This is used for the field weakening

 

 

 

 

 

current/short-circuit current

characteristic

p0322

 

 

 

 

Maximum motor speed

Maximum mechanical speed

p0323

 

 

 

 

Maximum motor current

De-magnetization protection

p0325

 

 

 

 

Motor pole position information

-

p0327

 

 

 

 

Optimum motor load angle

-

p0328

 

 

 

 

PE spindle, reluctance torque

-

 

 

 

 

 

constant

 

p0329

 

 

 

 

Motor pole position identification

-

 

 

 

 

 

current

 

P0341

 

 

 

 

Motor moment of inertia

For speed controller pre-control

p0342

 

 

 

 

Ratio between the total

-

 

 

 

 

 

motor moment of inertia

 

Drive Functions

149

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4