Function modules 7.9 Basic positioner

p2581 CO: EPOS software limit switch, plus

p2582 BI: EPOS software limit switch activation

r2683 CO/BO: EPOS status word 1

STOP cam

p2568 BI: EPOS STOP cam activation

p2569 BI: EPOS STOP cam, minus

p2570 BI: EPOS STOP cam, plus

r2684 CO/BO: EPOS status word 2

7.9.3Referencing

Features

Reference point offset (p2600)

Reversing cams (p2613, p2614)

Reference cam (p2612)

Binector input start (p2595)

Binector input setting (p2596)

Velocity override (p2646)

Reference point coordinate (p2598, p2599)

Selecting the referencing type (p2597)

Absolute encoder adjustment (p2507)

NOTICE

Referencing distance-coded zero marks is not supported.

Description

After a machine has been powered-up, for positioning, the absolute dimension reference must be established to the machine zero. This operation is known as referencing.

The following referencing types are possible:

Setting the reference point (all encoder types)

Incremental encoder

Active referencing (reference point approach (p2597 = 0)):

Reference cams and encoder zero mark (p2607 = 1)

Encoder zero mark (p0495 = 0)

External zero mark (p0495 ≠ 0)