Function modules

7.9Basic positioner

xx2x = ABS_POS -> p2648, p2651

xx3x = ABS_NEG -> p2648, p2652

Intermediate stop and canceling traversing block

The intermediate stop is activated by a 0 signal at p2640. After activation, the system brakes with the parameterized deceleration value (p2620 or p2645).

The current traversing task can be canceled by a 0 signal at p2641. After activation, the system brakes with the maximum deceleration (p2573).

The "intermediate stop" and "cancel traversing task" functions are only effective in the modes "traversing blocks" and "direct setpoint input/MDI".

Function diagrams (see SINAMICS S List Manual)

3618 EPOS - direct setpoint input mode/MDI, dynamic values

3620 EPOS - direct setpoint input mode/MDI

Overview of key parameters (see SINAMICS S List Manual)

p2577 BI: EPOS modulo offset activation

p2642 CI: EPOS direct setpoint input/MDI, position setpoint

p2643 CI: EPOS direct setpoint input/MDI, velocity setpoint

p2644 CI: EPOS direct setpoint input/MDI, acceleration override

p2645 CI: EPOS direct setpoint input/MDI, delay override

p2648 BI: EPOS direct setpoint input/MDI, positioning type

p2649 BI: EPOS direct setpoint input/MDI, acceptance type

p2650 BI: EPOS direct setpoint input/MDI, setpoint acceptance edge

p2651 BI: EPOS direct setpoint input/MDI, positive direction selection

p2652 BI: EPOS direct setpoint input/MDI, negative direction selection

p2653 BI: EPOS direct setpoint input/MDI, setup selection

p2654 CI: EPOS direct setpoint input/MDI, mode adaptation

p2690 CO: EPOS position, fixed setpoint

p2691 CO: EPOS velocity, fixed setpoint

p2692 CO: EPOS acceleration override, fixed setpoint

p2693 CO: EPOS delay override, fixed setpoint