Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Bit

Meaning

Remarks

BICO

Note:

The bidirectional digital inputs/outputs (DI/DO) can be connected as either an input or an output (see also receive signal A_DIGITAL).

MT_ZSW

Status word for the "central probe" function.

Table 10-26 Description of MT_ZSW (status word for the "central probe" function)

Bit

Meaning

 

Remarks

BICO

0

Digital input probe 1

Display of digital inputs

CO: r0688

1

Digital input probe 2

For telegram 392, in addition, probes 3 and 6

 

 

 

2

Digital input probe 3

 

 

3

Digital input probe 4

 

 

4

Digital input probe 5

 

 

5

Digital input probe 6

 

 

6...7

Reserved

 

8

Sub-sampling probe 1

Not yet carried out.

 

9

Sub-sampling probe 2

For telegram 392, in addition, probes 3 and 6

 

8

Sub-sampling probe 3

 

 

9

Sub-sampling probe 4

 

 

8

Sub-sampling probe 5

 

 

9

Sub-sampling probe 6

 

 

10...

Reserved

 

15

 

 

 

 

MTn_ZS_F and MTn_ZS_S

Display of the measuring time determined

The measuring time is specified as a 16-bit value with a resolution of 0.25 μs.

Features of the central probe

The time stamps from probes in more than one drive can be transferred simultaneously in a single telegram.

The time in the controller and drive unit is synchronized via the CU_STW and the CU_ZSW.

Note: The controller must support time synchronization!

A higher-level controller can then use the time stamp to determine the actual position value of more than one drive.

The system outputs a message if the measuring time determination function in the probe is already in use (see also p0488, p0489, and p0580).

388

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4