Efficient Networks S120 manual Limits, Maximum velocity

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 255
Image 255

Function modules 7.9 Basic positioner

With position tracking it is recommended to change p0412 or p2721.

Function diagrams (see SINAMICS S List Manual)

3635 Interpolator

4010 Position actual value conditioning

Overview of key parameters (see SINAMICS S List Manual)

p2576 EPOS modulo offset, modulo range

p2577 BI: EPOS modulo offset activation

p2583 EPOS backlash compensation

r2684 CO/BO: EPOS status word 2

r2685 CO: EPOS correction value

Commissioning with STARTER

In STARTER, the mechanical system screen form can be found under position control.

7.9.2Limits

Description

The velocity, acceleration and deceleration can be limited and the software limit switches and stop cams set.

Features

Traversing profile limits

Maximum velocity (p2571)

Maximum acceleration (p2572) / maximum deceleration (p2573)

Traversing range limits

Software limit switch (p2578, p2579, p2580, p2581, p2582)

STOP cams (p2568, p2569, p2570)

Jerk limitation

Jerk limitation (p2574)

Activation of jerk limitation (p2575)

Maximum velocity

The maximum velocity of an axis is defined using parameter p2571. The velocity should not be set to be greater than the maximum speeds in r1084 and r1087.

Drive Functions

255

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 255
Image 255
Efficient Networks S120 manual Limits, Maximum velocity