Basic information about the drive system 12.1 Parameter

Saving parameters in a non-volatile memory

The modified parameter values are stored in the volatile RAM. When the drive system is switched off, this data is lost.

The data has to be saved as follows in a non-volatile manner on the CompactFlash card so that it is available the next time the drive is switched on.

Save parameters - device and all drives p0977 = 1; automatically reset to 0

Save the parameters with STARTER See "Copy RAM to ROM" function

Resetting parameters

The parameters can be reset to the factory setting as follows:

Reset parameters - current drive object p0970 = 1; automatically reset to 0

Reset parameters - all parameters drive object "Control Unit" p0009 = 30 parameter reset

p0976 = 1; automatically reset to 0

Access level

The parameters are subdivided into access levels. The SINAMICS S List Manual specifies in which access level the parameter is displayed and can be changed. The required access levels 0 to 4 can be set in p0003.

Table 12-1 Access levels

Access level

0User-defined

1 Standard

2Extended

3 Expert

4 Service

Remark

Parameter from the user-defined list (p0013)

Parameters for the simplest operator functions (e.g. p1120 = ramp function generator ramp-up time).

Parameters to handle the basic functions of the device.

Expert knowledge is already required for this parameter (e.g. knowledge about BICO parameterization).

Please contact your local Siemens office for the password for parameters with access level 4 (Service). It must be entered into p3950.

Note

Parameter p0003 is CU-specific (belongs to Control Unit).

Drive Functions

469

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 469