Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Bit

Meaning

 

Comments

BICO

1

Ready to run

1

Ready to run

BO: r0899.1

 

 

 

DC link pre-charged, pulses inhibited

 

 

 

0

Not ready

 

2

Operation enabled

1

Operation enabled

BO: r0899.2

 

 

 

Vdc = Vdc_setp

 

 

 

0

Operation inhibited

 

3

Fault active

1

Fault active

BO: r2139.3

 

 

0

No fault

 

4

No OFF2 active

1

No OFF2 active

BO: r0899.4

 

 

0

OFF2 active

 

5

Reserved

6

Power-on disable

1

Power-on disable

BO: r0899.6

 

 

 

Fault active

 

 

 

0

No power-up inhibit

 

7

Alarm present

1

Alarm present

BO: r2139.7

 

 

0

No alarm

 

8

Reserved

9

Control requested

1

Control required

BO: r0899.9

 

 

 

The PLC is requested to assume control. Condition

 

 

 

 

for applications with isochronous mode: drive

 

 

 

 

synchronized with PLC system.

 

 

 

0

Local operation

 

 

 

 

Control only possible on device

 

10

Reserved

11

Bypass energized

1

Bypass energized

BO: r0899.11

 

 

 

Pre-charging is complete and the bypass relay for

 

 

 

 

the pre-charging resistors is energized.

 

 

 

0

Bypass not energized

 

 

 

 

Pre-charging not yet complete.

 

12

Line contactor activated

1

Line contactor activated

BO: r0899.12

 

 

0

Line contactor not energized

 

13...

Reserved

15

 

 

 

 

PosZSW

See function diagram [3645]

Table 10-16 Description of PosZSW (status word, positioning mode)

Bit

Meaning

 

Comments

BICO

0

Tracking mode active

1

Tracking mode active

BO: r2683.0

 

 

0

Tracking mode not active

 

1

Speed limiting active

1

Active

BO: r2683.1

 

 

0

Not active

 

Drive Functions

373