Efficient Networks S120 manual Active Infeed closed-loop control Chassis, Kdvvlv

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 24
Image 24

Infeed

1.1 Active Infeed

1.1.3Active Infeed closed-loop control Chassis

Schematic structure

&KDVVLV

&RQWURO8QLW

)LUPZDUH

6XSSO\V\VWHPGDWD

$FWLYH0DQLSXODWHG

,QIHHGYDULDEOHV $FWXDOYDOXHV

'5,9(&/L4

6XSSO\V\VWHP

0DLQVZLWFK

)XVHV

$FWLYH,QWHUIDFH0RGXOH

ZLWKSUHFKDUJLQJ

ZLWK960

:LWKOLQHILOWHU

ZLWKOLQHUHDFWRU

$FWLYH/LQH0RGXOH

'&OLQN

Figure 1-2 Schematic structure of Active Infeed

Operating mode of Active Infeed closed-loop control for Chassis Active Line Modules.

Active Line Modules Chassis only function in Active Mode.

In Active Mode, the DC link voltage is regulated to a variable setpoint (p3510), which results in a sinusoidal line current (cosφ = 1).

The DC link voltage setpoint (p3510) is preset depending on the supply voltage (p0210) using the equation p3510 = 1.5 * p0210.

Commissioning

The device supply voltage (p0210) must be parameterized during commissioning. The necessary line filter (p0220) is preset.

When it is first switched on with a new/modified network, an automatic controller setting should be implemented using the line/DC link identification routine (p3410).

Note

In a supply system without regenerative feedback capability (e.g. generators), regenerative operation must be inhibited via the binector input p3533.

The DC link voltage (p3510) can be set within the following limits:

Upper limit:

Maximum DC link voltage (p0280)

Product of line voltage (p0210) and max. step-up factor (r3508)

Lower limit: Supply voltage (p0210) multiplied by 1.42

24

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 24
Image 24