Efficient Networks S120 manual Commissioning the STO, SBC and SS1 functions, Commissioning notes

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 318
Image 318

Safety Integrated basic functions

9.7 Commissioning the "STO", "SBC" and "SS1" functions

"Simultaneously" means:

The changeover must be complete in both monitoring channels within the parameterized tolerance time.

p9650 SI tolerance time F-DI changeover (Control Unit)

p9850 SI tolerance time F-DI changeover (Motor Module)

If the "Safe Torque Off" function is not selected/deselected within the tolerance time, this is detected by the crosswise comparison, and fault F01611 or F30611 (STOP F) is output. In this case, the pulses have already been canceled as a result of the selection of "Safe Torque Off" on one channel.

9.7Commissioning the "STO", "SBC" and "SS1" functions

9.7.1General information about commissioning safety functions

Commissioning notes

NOTICE

For safety reasons, safety functions cannot be commissioned offline with the STARTER commissioning tool (or SCOUT).

Note

The "STO", "SBC" and "SS1" functions are drive specific, that is, the functions must be commissioned individually for each drive.

To support the "STO" and "SBC" functions, the following (minimum) safety versions are required:

Control Unit: V02.01.01 (r9770[0...2])

Motor Module: V02.01.01 (r9870[0...2])

To support the "SS1" functions, the following (minimum) safety version is required: Control Unit: V02.04.01 (r9770[0...2])

Motor Module: V02.04.01 (r9870[0...2])

If the version in the Motor Module is incompatible, the Control Unit responds as follows during the switchover to safety commissioning mode (p0010 = 95):

Fault F01655 (SI CU: Align the monitoring functions) is output. The fault triggers fault reaction OFF2.

The fault cannot be acknowledged until safety commissioning mode (p0010 ≠ 95) is exited.

The Control Unit triggers a safe pulse suppression via its own safety switch-off signal path.

If parameterized (p1215), the motor holding brake is applied.

The safety functions cannot be enabled (p9601/p9801 and p9602/p9802).