Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Bit

Meaning

 

Comments

BICO

 

Note:

 

 

 

 

This bit should not be set to "1" until the PROFIdrive has returned an appropriate status via STW1.9 = "1"..

11

Reserved

-

-

-

12

Reserved

-

-

-

13

Reserved

-

-

-

14

Reserved

-

-

-

15

Reserved

-

-

-

SATZANW (positioning mode, p0108.4 =1)

See function diagram [2476]

Table 10-8 Description of BLOCKSEL (positioning mode, p0108.4 =1)

Bit

Meaning

 

Comments

BICO

0

1 = block selection, bit 0 (20)

Block selection

BI: p2625

1

1 = block selection, bit 1 (21)

Traversing block 0 to 63

BI: p2626

2

1 = block selection, bit 2 (22)

 

 

BI: p2627

3

1 = block selection, bit 3 (23)

 

 

BI: p2628

4

1 = block selection, bit 4 (24)

 

 

BI: p2629

5

1 = block selection, bit 5 (25)

 

 

BI: p2630

6 ...

Reserved

-

-

-

14

 

 

 

 

15

Activate MDI

1

Activate MDI

p2647

 

 

0

De-activate MDI

 

Note:

 

 

 

 

See also: SINAMICS S Function Manual, Function module "basic positioner"

 

PosSTW (positioning mode, p0108.4 =1)

See function diagram [2477]

Table 10-9 Description of PosSTW (positioning mode, p0108.4 =1)

Bit

Meaning

 

Comments

BICO

0

Tracking mode

1

Activate tracking mode

BI: 2655

 

 

0

Tracking mode de-activated

 

1

Set reference point

1

Set reference point

BI: 2696

 

 

0

Do not set reference point

 

2

Reference cam

1

Reference cam active

BI: 2612

 

 

0

Reference cam not active

 

3

Fixed stop sensor active

1

The sensor for the fixed stop is active

BI: 2637

360

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 360
Image 360
Efficient Networks S120 manual Satzanw positioning mode, p0108.4 =1, PosSTW positioning mode, p0108.4 =1