Infeed

1.2 Smart Infeed

Overview: key parameters

p3624 Infeed harmonics controller order

p3625 Infeed harmonics controller scaling

r0069[0..6] Phase current, actual value

1.2Smart Infeed

1.2.1Smart Infeed closed-loop control

General

Note

Line Modules (Active Line Modules, Basic Line Modules, Smart Line Modules) of different types must not be operated simultaneously on the same DC link.

Features

For Smart Line Modules with a power of ≥ 16 kW

Unregulated DC link voltage

Regenerative feedback capability

Description

The firmware for the Smart Line Modules is on the Control Unit assigned to it. The Smart Line Module and Control Unit communicate via DRIVE-CLiQ.

Drive Functions

31

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 31
Image 31
Efficient Networks S120 manual Smart Infeed closed-loop control, Overview key parameters, Infeed Smart Infeed