Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Bit

Meaning

 

Comments

BICO

 

 

1/0

Ramp-up starts.

 

 

 

 

The start of the ramp-up procedure is detected as

 

 

 

 

follows:

 

 

 

 

The speed setpoint changes,

 

 

 

 

and

 

 

 

 

the defined tolerance bandwidth (p2164) is

 

 

 

 

exited.

 

 

 

0

Ramp-function generator active

 

 

 

 

The ramp-up procedure is still active once the

 

 

 

 

speed setpoint has been changed.

 

 

 

0/1

Ramp-up ends.

 

 

 

 

The end of the ramp-up procedure is detected as

 

 

 

 

follows:

 

 

 

 

The speed setpoint is constant,

 

 

 

 

and

 

 

 

 

The actual speed value is within the tolerance

 

 

 

 

bandwidth and has reached the speed setpoint,

 

 

 

 

and

 

 

 

 

The waiting time (p2166) has elapsed.

 

1

Torque utilization < p2194

1

Torque utilization < p2194

BO: r2199.11

 

 

 

The current torque utilization is less than the set

 

 

 

 

torque utilization threshold (p2194),

 

 

 

 

or

 

 

 

 

Ramp-up is not yet complete.

 

 

 

0

Torque utilization > p2194

 

 

 

 

The current torque utilization is greater than the

 

 

 

 

set torque utilization threshold (p2194).

 

 

Application:

 

 

 

 

This message indicates that the motor is overloaded and appropriate measures need to be taken to rectify the

 

situation (e.g. stop the motor or reduce the load).

 

2

n_act t p2161

1

n_act < p2161

BO: r2199.0

 

 

 

The actual speed value is less than the set

 

 

 

 

threshold value (p2161).

 

 

 

0

n_act ≥ p2161

 

 

 

 

The actual speed value is greater than or the same

 

 

 

 

as the set threshold value (p2161).

 

 

Note:

 

 

 

 

The message is parameterized as follows:

 

 

 

p2161 Threshold value

 

 

 

 

p2150 Hysteresis

 

 

 

 

Application:

 

 

 

 

To protect the mechanics, the gear stages are not switched mechanically until the speed is less than the set

 

threshold value.

 

 

 

3

n_act v p2155

1

n_act ≤ p2155

BO: r2197.1

 

 

 

The actual speed value is less than or the same as

 

 

 

 

the set threshold value (p2155).

 

 

 

0

n_act > p2155

 

 

 

 

The actual speed value is greater than the set

 

 

 

 

threshold value (p2155).

 