Efficient Networks S120 manual Description, Properties of the extended setpoint channel

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 48
Image 48

Extended setpoint channel 2.2 Description

2.2Description

In the extended setpoint channel, setpoints from the setpoint source are conditioned for motor control.

The setpoint for motor control can also originate from the technology controller (see "Technology controller").

 

 

6HWSRLQWVRXUFHV

 

 

0RWRUL]HG

$QDORJ

 

6SHHG

)LHOGEXV

-RJ

SRWHQWLRPHWHU

LQSXWV

IL[HGVHWSRLQWV

 

 

 

0DLQVHWSRLQW

6XSSOHPHQWDU\

 

 

 

VHWSRLQW

 

 

 

 

 

 

 

 

0DLQVXSSOHPHQWDU\VHWSRLQW

 

 

 

VHWSRLQWVFDOLQJ

 

 

6HWSRLQWFKDQQHO

 

 

 

 

 

 

 

'LUHFWLRQRIURWDWLRQOLPLWLQJ

 

 

 

GLUHFWLRQRIURWDWLRQFKDQJHRYHU

 

 

 

6XSSUHVVLRQEDQGZLGWKV

 

 

 

VHWSRLQWOLPLWDWLRQ

 

 

 

 

5DPSIXQFWLRQJHQHUDWRU

 

0RWRUFRQWURO

 

 

0RWRUFRQWURO

 

 

 

 

 

6HUYRYHFWRU

 

 

Figure 2-1 Extended setpoint channel

Properties of the extended setpoint channel

Main/supplementary setpoint, setpoint scaling

Direction of rotation limiting and direction of rotation changeover

Suppression bandwidths and setpoint limitation

Ramp function generator

Setpoint sources

The closed-loop control setpoint can be interconnected from various sources using BICO technology (e.g. to p1070 CI: main setpoint (see function diagram 3030)).

There are various options for setpoint input:

Fixed speed setpoints

Motorized potentiometer

48

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 48
Image 48
Efficient Networks S120 manual Description, Properties of the extended setpoint channel, Setpoint sources