Efficient Networks S120 manual Parameter value .. th parameter value, Parameter response Offset

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 404
Image 404

Communication PROFIBUS DP/PROFINET IO

10.1Communications according to PROFIdrive

Subindex:

0 dec ––> ID for the first array element.

1.parameter value ... 4th parameter value

Format:

07hex ––> Data type Unsigned32

08hex ––> Data type FloatingPoint

No. of values:

01hex ––> A value is written to each parameter in the specified format.

Value:

BICO input parameter: enter signal source.

Adjustable parameter: enter value

2.Invoke the parameter request.

3.Evaluate the parameter response.

Parameter response

 

Offset

Response header

Request reference mirrored

Response ID = 02 hex

0

 

= 40 hex

 

 

 

Axis mirrored = 02 hex

No. of parameters = 04 hex

2

Information about the parameter response:

Request reference mirrored:

This response belongs to the request with request reference 40.

Response ID:

02 hex ––> Write request positive

Axis mirrored:

02 hex ––> The value matches the value from the request.

No. of parameters:

04 hex ––> The value matches the value from the request.

404

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 404