Efficient Networks S120 manual Acceptance test for Safe Stop 1, time controlled SS1

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 330
Image 330

Safety Integrated basic functions 9.8 Acceptance test and certificate

No.

Description

Status

The following is tested:

Correct DRIVE-CLiQ wiring between Control Unit and Motor Modules

Correct assignment of drive No. – Motor Module – motor

The hardware is functioning properly

The switch-off signal paths are wired correctly

Correct assignment of the terminals for STO on the Control Unit

Correct STO grouping (if available)

Correct parameterization of the STO function

Routine for forced dormant error detection of the switch-off signal paths

9.8.4Acceptance test for Safe Stop 1, time controlled (SS1)

"Safe Stop 1" function (SS1, time-controlled)

This test comprises the following steps:

Table 9-11 "Safe Stop 1" function (SS1)

No.

 

Description

Status

1.

Initial state

 

 

Drive in "Ready" status (p0010 = 0)

 

 

STO function enabled (p9601.0 = 1, p9801.0 = 1)

 

 

Enable SS1 function (p9652 > 0, p9852 > 0)

 

 

No safety faults and alarms (r0945, r2122, r2132)

 

 

r9772.0

= r9772.1 = 0 (STO de-selected and inactive – CU)

 

 

r9872.0

= r9872.1 = 0 (STO de-selected and inactive – MM)

 

 

r9773.0

= r9773.1 = 0 (STO de-selected and inactive – drive)

 

 

r9772.2

= r9872.2 = 0 (SS1 not requested – CU and MM)

 

 

When terminals are grouped for "Safe Torque Off":

 

 

r9774.0

= r9774.1 = 0 (STO de-selected and inactive - group)

 

2.

Run the drive

 

3.

Ensure that the correct drive is running

 

4.

Select SS1 when issuing the traversing command

 

Note:

The acceptance test must be carried out for each configured control, which may be via terminals, via the TM54F or via PROFIsafe.

5. Check the following:

The drive is braked along the OFF3 ramp (p1135).

Before the SS1 delay time (p9652, p9852) expires, the following applies:

r9772.0 = r9772.1 = 0 (STO deselected and inactive - CU)

r9872.0 = r9872.1 = 0 (STO de-selected and inactive – MM)

r9772.2 = r9872.2 = 1 (SS1 active – CU and MM)

330

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 330
Image 330
Efficient Networks S120 Acceptance test for Safe Stop 1, time controlled SS1, Safe Stop 1 function SS1, time-controlled