Basic information about the drive system 12.10 Rules for wiring with DRIVE-CLiQ

Servo

Vector V/f (=vector without speed control function module)

Vector

Notes on the maximum number of drives that can be controlled by a CU320:

In addition, the "Safe Standstill" function can be activated and a TM31 connected.

No function modules must be activated.

Rules for FW2.3

● The default sampling times must not be changed.

Table 12-18 Maximum number of drives that can be controlled by a Control Unit 320

 

Servo

Vector V/f (=vector

 

 

without speed control

 

 

function module)

Number of

1 Active Line Module +

1 Active Line Module +

components

6 Motor Modules

4 Motor Modules

 

 

(sampling time of current

 

 

controller 250 µs / speed

 

 

controller 1000 µs)

 

 

1 Active Line Module +

 

 

6 Motor Modules

 

 

(sampling time of current

 

 

controller 400 µs / speed

 

 

controller 1600 µs)

 

 

1 Active Line Module +

 

 

10 Motor Modules

 

 

(sampling time of current

 

 

controller 500 µs / speed

 

 

controller 4000 µs)

 

Servo and vector V/f:

 

 

1 Active Line Module + 5 Motor Modules

 

(servo: Current controller 125 µs / speed controller

 

125 µs vector V/f:

 

 

sampling time of current controller 250 µs with max.

 

2 V/f drives

 

 

Sampling time of current controller 400 µs with more

 

than 2 V/f drives)

 

Vector

1 Active Line Module +

2 Motor Modules (sampling time of current controller 250 µs / speed controller 1000 µs)

1 Active Line Module +

4 Motor Modules (sampling time of current controller 400 µs / speed controller 1600 µs)

Notes on the maximum number of drives that can be controlled by a CU320:

In addition, the "Safe Standstill" function can be activated and a TM31 connected.

No function modules must be activated.

Drive Functions

511

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 511
Image 511
Efficient Networks S120 manual Rules for FW2.3, Servo