Basic information about the drive system 12.5 Inputs/outputs

12.5.2Digital inputs/outputs

Digital inputs

;

0

;

0



 

;

9

 

S

 U

;

',

; 0

; 0

9



9



S

U



Figure 12-9 Digital inputs: signal processing using DI 0 of CU320 as an example

Properties

The digital inputs are "high active".

An open input is interpreted as "low".

Fixed debouncing setting

Delay time = 1 to 2 current controller cycles (p0115[0])

Availability of the input signal for further interconnection

inverted and not inverted as a binector output

as a connector output

Simulation mode settable and parameterizable.

CU320: Isolation block by block, set by jumper.

Jumper open: electrically isolated.

The digital inputs function only if a reference ground is connected.

Jumper closed, non-floating.

The reference potential of the digital inputs is the ground of the Control Unit.

Sampling time for digital inputs/outputs adjustable on CU320 (p0799)

Function diagrams (see SINAMICS S List Manual)

● 2020 Digital inputs, electrically isolated (DI 0 ... DI 3) ● 2120 Digital inputs, electrically isolated (DI 0 ... DI 3) ● 2121 Digital inputs, electrically isolated (DI 4 ... DI 7)

Drive Functions

485

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4