Efficient Networks S120 manual AktSatz

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 374
Image 374

Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Bit

Meaning

 

Comments

BICO

2

Setpoint static

1

Setpoint static

BO: r2683.2

 

 

0

Setpoint not static

 

3

Reserved

4

Axis moves forwards

1

Axis moves forwards

BO: r2683.4

 

 

0

Axis stationary or moving backwards

 

5

Axis moving backwards

1

Axis moving backwards

BO: r2683.5

 

 

0

Axis stationary or moving forwards

 

6

Software limit switch minus

1

Software limit switch minus approached

BO: r2683.6

 

approached

0

Software limit switch minus not approached

 

 

 

 

7

Software limit switch plus

1

Software limit switch plus approached

BO: r2683.7

 

approached

0

Software limit switch plus not approached

 

 

 

 

8

Actual position value <= cam

1

Actual position value <= cam switching position 1

BO: r2683.8

 

switching position 1

0

Cam switching position 1 passed

 

 

 

 

9

Actual position value <= cam

1

Actual position value <= cam switching position 2

BO: r2683.9

 

switching position 2

0

Cam switching position 2 passed

 

 

 

 

10

Direct output 1 via the traversing

1

Direct output 1 active

BO: r2683.10

 

block

0

Direct output 1 not active

 

 

 

 

11

Direct output 2 via the traversing

1

Direct output 1 active

BO: r2683.11

 

block

0

Direct output 1 not active

 

 

 

 

12

Fixed stop reached

1

Fixed stop reached

BO: r2683.12

 

 

0

Fixed stop is not reached

 

13

Fixed stop, clamping torque

1

Fixed stop, clamping torque reached

BO: r2683.13

 

reached

0

Fixed stop, clamping torque is not reached

 

 

 

 

14

Travel to fixed stop active

1

Travel to fixed stop active

BO: r2683.12

 

 

0

Travel to fixed stop not active

 

15

Reserved

AktSatz

See function diagram [3650]

Table 10-17 Description AktSatz (active traversing block/MDI active)

Bit

Meaning

 

Comments

BICO

0

Active traversing block, bit 0

Active traversing block (6-bit counter)

BO: r2670.0

1

Active traversing block, bit 1

 

BO: r2670.1

2

Active traversing block, bit 2

 

BO: r2670.2

3

Active traversing block, bit 3

 

BO: r2670.3

4

Active traversing block, bit 4

 

BO: r2670.4

5

Active traversing block, bit 5

 

BO: r2670.5

6..14

Reserved

15

MDI active

1

MDI active

BO: r2670.15

 

 

0

MDI not active

 

374

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 374
Image 374
Efficient Networks S120 manual AktSatz