Basic information about the drive system 12.9 DRIVE-CLiQ topology

12.9DRIVE-CLiQ topology

Introduction

The term topology is used in SINAMICS to refer to a wiring harness with DRIVE-CLiQ cables. A unique component number is allocated to each component during the start-up phase.

DRIVE-CLiQ (Drive Component Link with IQ) is a communication system for connecting the various components in SINAMICS (e.g. Control Unit, Line Module, Motor Modules, motors, and encoders).

DRIVE-CLiQ supports the following properties:

Automatic detection of components by the Control Unit

Standard interfaces to all components

Standardized diagnostics down to component level

Standardized service down to component level

Electronic rating plate

The electronic type plate contains the following data:

Component type (e.g. SMC20)

Order number (e.g. 6SL3055-0AA0-5BA0)

Manufacturer (e.g. SIEMENS)

Hardware version (e.g. A)

Serial number (e.g. "T-PD3005049)

Technical specifications (e.g. rated current)

Actual topology

The actual topology is the actual DRIVE-CLiQ wiring harness.

When the drive system components are started up, the actual topology is detected automatically via DRIVE-CLiQ.

Target topology

The target topology is stored on the CompactFlash card on the Control Unit and is compared with the actual topology when the Control Unit is started up.

The target topology can be specified in two ways and saved on the CompactFlash card:

Via STARTER

by creating the configuration and loading it onto the drive

Via quick commissioning (automatic configuration):

the actual topology is read and the target topology written to the CompactFlash card.