Efficient Networks S120 manual Example central probe, Motion Control with PROFIdrive Description

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 389
Image 389

Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Example: central probe

Assumptions for the example:

Determination of the time stamp MT1_ZS_S by evaluating the rising edge of probe 1

Determination of the time stamp MT2_ZS_S and MT2_ZS_F by evaluating the rising and falling edge of probe 2

Probe 1 on DI/DO 9 of the Control Unit (p0680[0] = 1)

Probe 2 on DI/DO 10 of the Control Unit (p0680[1] = 2)

Manufacturer-specific telegram p0922 = 391 is set.

07B67:



 

 



3UREH



 

 



9DOXHH[LVWV



07B=6B6



 

07B67:



 

 



07B67:



 

 



3UREH



 

 



9DOXHH[LVWV



07B=6B6



 

9DOXHH[LVWV



07B=6B)



 

Figure 10-17 Function chart for central probe example

10.1.3.7Motion Control with PROFIdrive

Description

The "Motion control with PROFIBUS" or "Motion Control with PROFINET" function can be used to implement an isochronous drive link between a master and one or more slaves via the PROFIBUS field bus or an isochronous drive link via PROFINET.

Note

The isochronous drive link is defined in the following documentation:

Reference: /P5/ PROFIdrive Profile Drive Technology

Drive Functions

389

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 389
Image 389
Efficient Networks S120 manual Example central probe, Motion Control with PROFIdrive Description