Servo control

3.12 Motor data identification

Determined data (gamma)

Data that are accepted (p1960 = 1)

Note:

The magnetic design of the motor can be identified from the saturation characteristic.

r1969 moment of inertia identified

p0341 motor moment of inertia

 

* p0342 ratio between the total moment of inertia and that of the

 

motor

 

+ p1498 load moment of inertia

r1973 encoder pulse number identified

-

Note:

The encoder pulse number is only determined with a very high degree of inaccuracy (p0407/p0408) and is only suitable for making rough checks. The sign is negative if inversion is required (p0410.0).

3.12.2Motor data identification - synchronous motor

Synchronous motor

Table 3-13 Data determined using p1910 for synchronous motors (stationary measurement)

Determined data

Data that are accepted (p1910 = 1)

r1912 stator resistance identified

p0350 motor stator resistance, cold

 

+ p0352 cable resistance

r1925 threshold voltage identified

-

r1932 d inductance

p0356 motor stator leakage inductance

 

+ p0353 motor series inductance

 

p1715 current controller P gain

 

p1717 current controller integral-action time

r1934 q inductance identified

-

r1950 voltage emulation error

p1952 voltage emulation error, final value

voltage values

 

r1951 voltage emulation error, current values

p1953 voltage emulation error, current offset

Note regarding r1950 to p1953:

Active when the function module "extended torque control" is activated and activated compensation of the voltage emulation error (p1780.8 = 1).

r1973 encoder pulse number identified

-

Note:

The encoder pulse number is only determined with a very high degree of inaccuracy (p0407/p0408) and is only suitable for making rough checks. The sign is negative if inversion is required (p0410.0).

r1984 Pole position identification angular difference p0431 Angular commutation offset

Note:

r1984 indicates the difference of the angular commutation offset before being transferred into p0431.

-

p0410 encoder inversion actual value

Note:

If the encoder inversion is changed using MotID, fault F07993 is output, which refers to a possible change in the direction of rotation and can only be acknowledged by p1910 = -2.