Efficient Networks S120 manual Safe Brake Control SBC, Status for Safe Stop

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 312
Image 312

Safety Integrated basic functions 9.5 Safe Brake Control (SBC)

Status for "Safe Stop 1"

The status of the "Safe Stop 1" function is displayed using the following parameters:

r9772 CO/BO: SI status (Control Unit)

r9773 CO/BO: SI status (Control Unit + Motor Module)

r9774 CO/BO: SI status (Safe Torque Off group)

r9872 CO/BO: SI status (Motor Module)

Alternatively, the status of the functions can be displayed using the configurable messages N01621 and N30621 (configured using p2118 and p2119).

Overview of key parameters (see SINAMICS S List Manual)

see "Safe Torque Off" function

p1135 OFF3 ramp-down time

p9652 SI Safe Stop 1 delay time (Control Unit)

p9852 SI Safe Stop 1 delay time (Motor Module)

9.5Safe Brake Control (SBC)

Description

Safe brake control is used to activate holding brakes that function according to the standby current principle (e.g. motor holding brake).

The command for releasing or applying the brake is transmitted to the Motor Module/Power Module via DRIVE-CLiQ. he Motor Module/Safe Brake Relay then carries out the action and activates the outputs for the brake.

Brake activation via the brake connection on the Motor Module/Safe Brake Relay is carried out using a safe, two-channel method.

Note

Chassis components do not support this function.

Note

To ensure that this function can be used for Power Modules Blocksize, a Safe Brake Relay must be used (for more information, see the Equipment Manual).

When the Power Module is configured automatically, the Safe Brake Relay is detected and the motor holding brake type is defaulted (p1278 = 0).

312

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 312
Image 312