Basic information about the drive system 12.1 Parameter

– DDS: Drive Data Set

The drive data set contains the parameters for switching between different drive control configurations.

The CDS and DDS can be switched over during normal operation. Further types of data set also exist, however these can only be activated indirectly by means of a DDS switchover.

EDS Encoder Data Set

MDS Motor Data Set

7HUPLQDO0RGXOH

2SWLRQ%RDUG

,QIHHG

'ULYHQ

'ULYH

'ULYH

'DWDVHWLQGHSHQGHQW

GULYHSDUDPHWHUV

&'6&RPPDQG'DWD6HW

''6'ULYH'DWD6HW



0RWRUVHOHFWLRQ

(QFRGHUVHOHFWLRQ

(QFRGHUVHOHFWLRQ

(QFRGHUVHOHFWLRQ



('6(QFRGHU'DWD6HW

0'60RWRU'DWD6HW

Figure 12-2 Parameter categories