Efficient Networks S120 Controlling the drive using the BOP20, Displaying alarms, Bit r0019 Name

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 498
Image 498

Basic information about the drive system

12.6 Parameterizing using the BOP20 (Basic Operator Panel 20)

Displaying alarms

$$ODUP

1HZDODUPVRUDODUPVSUHVHQW

DQGQRNH\SUHVVHGIRUDSSUR[

VHFRQGV

0RUHWKDQRQHDODUP

IURPWKHDFWLYHGULYH

DQGDQRWKHUGULYH

DIWHUVHFRQGV

$ODUPVDUHFORFNHGWKURXJKDXWRPDWL FDOO\

DIWHUVHFRQGV

DIWHUVHFRQGV

Figure 12-20 Alarms

12.6.4Controlling the drive using the BOP20

Description

When commissioning the drive, it can be controlled via the BOP20. A control word is available on the Control Unit drive object (r0019) that can be interconnected with the appropriate binector inputs e.g. of the drive or the infeed.

The interconnections do not function if a standard PROFIdrive telegram was selected as its interconnection cannot be disconnected.

Table 12-10 BOP20 control word

Bit (r0019)

Name

Example, interconnection parameters

0

ON / OFF (OFF1)

p0840

1

No coast down/coast down (OFF2)

p0844

2

No fast stop/fast stop (OFF3)

p0848

Note:

For simple commissioning, only bit 0 should be interconnected. When interconnecting bits 0 ... 2, then the system is powered-down according to the following priority: OFF2, OFF3, OFF1.

7

Acknowledge fault (0 -> 1)

p2102

13

Motorized potentiometer, raise

p1035

14

Motorized potentiometer, lower

p1036

498

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 498
Image 498
Efficient Networks S120 manual Controlling the drive using the BOP20, Displaying alarms, Bit r0019 Name, On / OFF OFF1