Efficient Networks S120 Password, Parameter overview for password see Sinamics S List Manual

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 305
Image 305

Safety Integrated basic functions 9.1 General information

Password

The safety password protects the safety parameters against unauthorized write access.

In commissioning mode for Safety Integrated (p0010 = 95), you cannot change safety parameters until you have entered the valid safety password in p9761 for the drives or p10061 for the TM54F.

When Safety Integrated is commissioned for the first time, the following applies:

Safety password = 0

Default setting for p9761 = 0

In other words:

The safety password does not need to be set during initial commissioning.

In the case of a series commissioning of Safety or in the case of spare part installation, the following applies:

The safety password is retained on the CF card and in the STARTER project.

No safety password is required in the case of spare part installation.

Change password for the drives

p0010 = 95 Commissioning mode

p9761 = Enter "old safety password".

p9762 = Enter "new password".

p9763 = Confirm "new password".

The new and confirmed safety password is valid immediately.

Change password for the TM54F

p0010 = 95 Commissioning mode

p10061 = Enter "Old TM54F Safety Password" (factory setting "0")

p10062 = Enter "new password"

p10063 = Acknowledge "new password"

The new and acknowledged safety password is valid immediately.

If you need to change safety parameters but you do not know the safety password, proceed as follows:

1.Set the entire drive unit (Control Unit with all connected drives/components) to the factory setting.

2.Recommission the drive unit and drives.

3.Recommission Safety Integrated.

Parameter overview for password (see SINAMICS S List Manual)

p9761 SI password input

p9762 SI password new

p9763 SI password acknowledgement

p10061 SI password input TM54F

Drive Functions

305

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 305
Image 305
Efficient Networks S120 manual Password, Parameter overview for password see Sinamics S List Manual