Horizontal Position
make−up box

Horizontal Position

HORIZONTAL LEFT POSITION

 

Top Vent Discharge

vent pipe

pressure switch

flue

 

transition

AIR

 

FLOW

cover plate

collector box

SDisconnect pressure switch hose from barbed fitting on the pres- sure switch assembly. Remove pressure switch assembly (1 screw) and cut wire tie to free pressure switch wires. Re−install pressure switch on the other side of orifice plate and re−connect pressure switch hose.

SRe−secure pressure switch wires by either pulling excess wires through the blower compartment and securing with supplied wire tie or coil excess wire and secure to the gas manifold.

FIGURE 18

HORIZONTAL LEFT POSITION

Side Vent Discharge

pressure switch

AIR

FLOW

flue transition

make−up box

collector box

 

SDisconnect pressure switch hose from barbed fitting on the pressure switch assembly. Remove pressure switch assembly (1 screw) and cut wire tie to free pressure switch wires. Re− install pressure switch on the other side of orifice plate and re− connect pressure switch hose.

SRe−secure pressure switch wires by either pulling excess wires through the blower compartment and securing with supplied wire tie, or coil excess wire and secure to the gas manifold.

HORIZONTAL RIGHT POSITION

Top Vent Discharge

vent pipe

flue transition

pressure switch

cover plate

AIR

FLOW

collector box

make−up box

SGas supply piping must be brought into the unit from the bottom in order to accommodate the flue pipe.

SRemove make−up box assembly (2 screws) and cut wire tie to free make−up box wires. Re−install make−up box on other side of cabinet.

SRe−secure make−up box wires by either pulling excess wires through the blower compartment and securing with supplied wire tie, or coil excess wire and secure to the gas manifold.

FIGURE 20

 

HORIZONTAL RIGHT POSITION

 

Side Vent Discharge

 

pressure switch

AIR

 

FLOW

flue transition

 

 

collector box

 

make up box

 

FIGURE 21

FIGURE 19