BLOWER DATA

SL280UH090V36B BLOWER PERFORMANCE (less filter)

BOTTOM RETURN AIR

0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range

HEATING

1 Heating Speed

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

First Stage Heating Speed - cfm

 

 

Second Stage Heating Speed - cfm

 

Settings

 

 

 

 

 

 

 

 

 

 

 

+24%

 

1300

 

 

 

1420

 

 

+18%

 

1250

 

 

 

1335

 

 

+12%

 

1185

 

 

 

1285

 

 

+6%

 

1145

 

 

 

1240

 

 

Factory Default

 

1070

 

 

 

1170

 

 

–6%

 

1015

 

 

 

1100

 

 

–12%

 

970

 

 

 

1035

 

 

–18%

 

880

 

 

 

980

 

 

 

 

 

COOLING

 

 

 

 

 

 

1 Cooling Speed

 

First Stage Cooling Speed - cfm

 

 

Second Stage Cooling Speed - cfm

 

DIP Switch

Low

Medium-Low

Medium-High

 

2 High

Low

 

Medium-Low

Medium-High

 

2 High

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

616

755

846

 

980

1018

 

1197

1291

 

1399

Factory Default

571

698

767

 

886

909

 

1083

1197

 

1284

489

627

681

 

812

834

 

968

1081

 

1179

SINGLE SIDE RETURN AIR

0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range

HEATING

1 Heating Speed

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

First Stage Heating Speed - cfm

 

 

Second Stage Heating Speed - cfm

 

Settings

 

 

 

 

 

 

 

 

 

 

 

+24%

 

1305

 

 

 

1425

 

 

+18%

 

1250

 

 

 

1350

 

 

+12%

 

1195

 

 

 

1290

 

 

+6%

 

1135

 

 

 

1230

 

 

Factory Default

 

1070

 

 

 

1165

 

 

–6%

 

995

 

 

 

1100

 

 

–12%

 

935

 

 

 

1030

 

 

–18%

 

870

 

 

 

960

 

 

 

 

 

COOLING

 

 

 

 

 

 

1 Cooling Speed

 

First Stage Cooling Speed - cfm

 

 

Second Stage Cooling Speed - cfm

 

DIP Switch

Low

Medium-Low

Medium-High

 

2 High

Low

 

Medium-Low

Medium-High

 

2 High

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

611

731

830

 

971

995

 

1160

1274

 

1376

Factory Default

575

674

748

 

870

889

 

1075

1160

 

1270

519

604

691

 

786

808

 

952

1056

 

1147

1Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.

2Factory default setting.

NOTES - The effect of static pressure is included in air volumes shown.

First stage HEAT is approximately 91% of the same second stage HEAT.

First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 500 cfm. Lennox Harmony III™ Zone Control Applications - Minimum blower speed is 455 cfm.