BLOWER DATA

SL280UH110V60C BLOWER PERFORMANCE (less filter)

BOTTOM RETURN AIR, RETURN AIR FROM BOTH SIDES OR RETURN AIR FROM BOTTOM AND ONE SIDE 0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range

HEATING

1 Heating Speed

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

First Stage Heating Speed - cfm

 

 

Second Stage Heating Speed - cfm

 

Settings

 

 

 

 

 

 

 

 

 

 

 

+24%

 

1690

 

 

 

1855

 

 

+18%

 

1605

 

 

 

1765

 

 

+12%

 

1525

 

 

 

1675

 

 

+6%

 

1445

 

 

 

1585

 

 

Factory Default

 

1360

 

 

 

1495

 

 

–6%

 

1280

 

 

 

1405

 

 

–12%

 

1200

 

 

 

1315

 

 

–18%

 

1115

 

 

 

1230

 

 

 

 

 

COOLING

 

 

 

 

 

 

1 Cooling Speed

 

First Stage Cooling Speed - cfm

 

 

Second Stage Cooling Speed - cfm

 

DIP Switch

Low

Medium-Low

Medium-High

 

2 High

Low

 

Medium-Low

Medium-High

 

2 High

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

1060

1220

1330

 

1565

1535

 

1710

1910

 

2210

Factory Default

970

1075

1180

 

1430

1400

 

1565

1715

 

2015

875

980

1070

 

1255

1260

 

1400

1560

 

1815

SINGLE SIDE RETURN AIR

0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range

HEATING

1 Heating Speed

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

First Stage Heating Speed - cfm

 

 

Second Stage Heating Speed - cfm

 

Settings

 

 

 

 

 

 

 

 

 

 

 

+24%

 

1640

 

 

 

1805

 

 

+18%

 

1560

 

 

 

1715

 

 

+12%

 

1480

 

 

 

1630

 

 

+6%

 

1400

 

 

 

1545

 

 

Factory Default

 

1325

 

 

 

1455

 

 

–6%

 

1245

 

 

 

1370

 

 

–12%

 

1165

 

 

 

1280

 

 

–18%

 

1085

 

 

 

1195

 

 

 

 

 

COOLING

 

 

 

 

 

 

1 Cooling Speed

 

First Stage Cooling Speed - cfm

 

 

Second Stage Cooling Speed - cfm

 

DIP Switch

Low

Medium-Low

Medium-High

 

2 High

Low

 

Medium-Low

Medium-High

 

2 High

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

1020

1160

1285

 

1550

1505

 

1690

1855

 

2125

Factory Default

940

1050

1155

 

1400

1375

 

1525

1685

 

1935

835

945

1020

 

1250

1235

 

1380

1505

 

1730

1Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.

2Factory default setting.

NOTES - The effect of static pressure is included in air volumes shown.

First stage HEAT is approximately 91% of the same second stage HEAT.

First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 500 cfm. Lennox Harmony III™ Zone Control Applications - Minimum blower speed is 485 cfm.