BLOWER DATA

SL280UH135V60D BLOWER PERFORMANCE (less filter)

BOTTOM RETURN AIR, RETURN AIR FROM BOTH SIDES OR RETURN AIR FROM BOTTOM AND ONE SIDE 0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range

HEATING

1 Heating Speed

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

First Stage Heating Speed - cfm

 

 

Second Stage Heating Speed - cfm

 

Settings

 

 

 

 

 

 

 

 

 

 

 

+24%

 

1875

 

 

 

2065

 

 

+18%

 

1785

 

 

 

1965

 

 

+12%

 

1695

 

 

 

1865

 

 

+6%

 

1605

 

 

 

1765

 

 

Factory Default

 

1515

 

 

 

1665

 

 

–6%

 

1425

 

 

 

1565

 

 

–12%

 

1330

 

 

 

1465

 

 

–18%

 

1240

 

 

 

1365

 

 

 

 

 

COOLING

 

 

 

 

 

 

1 Cooling Speed

 

First Stage Cooling Speed - cfm

 

 

Second Stage Cooling Speed - cfm

 

DIP Switch

Low

Medium-Low

Medium-High

 

2 High

Low

 

Medium-Low

Medium-High

 

2 High

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

1025

1120

1325

 

1650

1500

 

1600

1840

 

2235

Factory Default

965

1015

1180

 

1490

1420

 

1510

1700

 

2110

875

930

1060

 

1350

1225

 

1320

1505

 

1840

SINGLE SIDE RETURN AIR

0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range

HEATING

1 Heating Speed

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

First Stage Heating Speed - cfm

 

 

Second Stage Heating Speed - cfm

 

Settings

 

 

 

 

 

 

 

 

 

 

 

+24%

 

1850

 

 

 

2035

 

 

+18%

 

1760

 

 

 

1935

 

 

+12%

 

1670

 

 

 

1835

 

 

+6%

 

1580

 

 

 

1740

 

 

Factory Default

 

1490

 

 

 

1640

 

 

–6%

 

1400

 

 

 

1540

 

 

–12%

 

1310

 

 

 

1445

 

 

–18%

 

1225

 

 

 

1345

 

 

 

 

 

COOLING

 

 

 

 

 

 

1 Cooling Speed

 

First Stage Cooling Speed - cfm

 

 

Second Stage Cooling Speed - cfm

 

DIP Switch

 

 

 

 

 

 

 

 

 

 

 

Low

Medium-Low

Medium-High

 

2 High

Low

 

Medium-Low

Medium-High

 

2 High

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

1030

1105

1305

 

1635

1525

 

1600

1840

 

2255

Factory Default

960

1005

1175

 

1480

1355

 

1435

1635

 

2035

845

925

1050

 

1340

1240

 

1315

1520

 

1850

1Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.

2Factory default setting.

NOTES - The effect of static pressure is included in air volumes shown.

First stage HEAT is approximately 91% of the same second stage HEAT.

First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 500 cfm. Lennox Harmony III™ Zone Control Applications - Minimum blower speed is 426 cfm.