Efficient Networks S120 manual Basic Infeed open-loop control, Infeed Basic Infeed

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 38
Image 38

Infeed

1.3 Basic Infeed

Signal name

Internal status

Parameter

PROFIdrive telegram 370

 

word

 

 

Pre-charging completed

ZSWAE.11

r0899.11

A_ZSW1.11

Line contactor energized feedback

ZSWAE.12

r0899.12

A_ZSW1.12

1.3Basic Infeed

1.3.1Basic Infeed open-loop control

General

Note

Line Modules (Active Line Modules, Basic Line Modules, Smart Line Modules) of different types must not be operated simultaneously on the same DC link.

Features

For Basic Line Modules Chassis and Booksize

Unregulated DC link voltage

Intregrated control of external braking resistors with 20 kW and 40 kW Basic Line Modules (with temperature monitoring)

Description

Basic Infeed open-loop control can be used to switch on/off the Basic Line Module. The Basic Line Module is an unregulated infeed unit without regenerative feedback capability.

The open-loop control firmware for the Basic Line Module runs on the Control Unit assigned to it. The Basic Line Module and Control Unit communicate via DRIVE-CLiQ.

38

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 38
Image 38
Efficient Networks S120 manual Basic Infeed open-loop control, Infeed Basic Infeed