Efficient Networks S120 manual Sample wiring for vector drives, $FWLYH LQH 0RGXOH

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 514
Image 514

Basic information about the drive system 12.10 Rules for wiring with DRIVE-CLiQ

12.10.3Sample wiring for vector drives

Drive line-up comprising three Motor Modules (chassis) with identical pulse frequencies or vector (booksize)

Motor Modules (chassis) with identical pulse frequencies or vector (booksize) can be connected to a DRIVE-CLiQ interface on the Control Unit.

In the following diagram, three Motor Modules are connected to interface X101.

Note

This topology does not match the topology created offline by STARTER and must be changed.

&8



;

;

;

;

,QIHHG

$FWLYH

/LQH

0RGXOH

;

;

;

$FWLYH

,QWHUIDFH

0RGXOH

;

960

'ULYH

6LQJOH

0RWRU

0RGXOH

;

;

;

;

;

60&



0

'ULYH

6LQJOH

0RWRU

0RGXOH

;

;

;

;

;

60&



0

'ULYH

6LQJOH

0RWRU

0RGXOH

;

;

;

;

;

60&



0

'5,9(&/L4

 

 

HQFRGHU

 

3RZHUUDWLQJ

Figure 12-25 Drive line-up (chassis) with identical pulse frequencies

Drive line-up comprising four Motor Modules (chassis) with different pulse frequencies

Motor Modules with different pulse frequencies must be connected to different DRIVE-CLiQ interfaces on the Control Unit.

In the following diagram, two Motor Modules (400 V, output ≤ 250 kW, pulse frequency

2 kHz) are connected to interface X101 and two Motor Modules (400 V, output > 250 kW, pulse frequency 1.25 kHz) are connected to interface X102.