12.5Inputs/outputs

9100 Digital inputs, electrically isolated (DI 0 ... DI 3)

9400 Digital inputs/outputs, bidirectional (DI 0 ... DI 7)

9401 Digital inputs/outputs, bidirectional (DI 8 ... DI 15)

9402 Digital inputs/outputs, bidirectional (DI 16 ... DI 23)

9550 Digital inputs, electrically isolated (DI 0 ... DI 3)

9552 Digital inputs, electrically isolated (DI 4 ... DI 7)

9660 Digital inputs, electrically isolated (DI 0 ... DI 3)

Digital outputs

 

S

S 







 

 

1H[WVXSSO\

 

0H[W

;

 

0H[W

;

 

 



 

9H[W

;

 

9H[W

;

9

'2

;

 

9

 

 

 

U

 

Figure 12-10 Digital outputs: signal processing using DO 0 of TB30 as an example

Properties

Separate power supply for the digital outputs.

Source of output signal can be selected by parameter.

Signal can be inverted by parameter.

Status of output signal can be displayed

as a binector output

as a connector output

Note

Before the digital outputs can function, their own electronics power supply must be connected.

Function diagrams (see SINAMICS S List Manual)

9102 Electrically isolated digital outputs (DO 0 to DO 3)

9556 Digital relay outputs, electrically isolated (DO 0 and DO 1)