Efficient Networks S120 manual Cuzsw status word for Control Unit, CU

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 386
Image 386

Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

Bit

Meaning

 

Remarks

BICO

1

Digital input/output 9

DI/DO 9 on the Control Unit must be parameterized as an output

BI: p0739

 

(DI/DO 9)

 

(p0728.9 = 1).

 

2

Digital input/output 10

DI/DO 10 on the Control Unit must be parameterized as an output

BI: p0740

 

(DI/DO 10)

 

(p0728.10 = 1).

 

3

Digital input/output 11

DI/DO 11 on the Control Unit must be parameterized as an output

BI: p0741

 

(DI/DO 11)

 

(p0728.11 = 1).

 

4

Digital input/output 12

DI/DO 12 on the Control Unit must be parameterized as an output

BI: p0742

 

(DI/DO 12)

 

(p0728.12 = 1).

 

5

Digital input/output 13

DI/DO 13 on the Control Unit must be parameterized as an output

BI: p0743

 

(DI/DO 13)

 

(p0728.13 = 1).

 

6

Digital input/output 14

DI/DO 14 on the Control Unit must be parameterized as an output

BI: p0744

 

(DI/DO 14)

 

(p0728.14 = 1).

 

7

Digital input/output 15

DI/DO 15 on the Control Unit must be parameterized as an output

BI: p0745

 

(DI/DO 15)

 

(p0728.15 = 1).

 

8...

Reserved

15

 

 

 

 

Note:

The bidirectional digital inputs/outputs (DI/DO) can be connected as either an input or an output (see also transmit signal E_DIGITAL).

MT_STW

Control word for the "central probe" function. Display via r0685.

Table 10-23 Description of MT_STW (control word for Control Unit)

Bit

Meaning

 

Remarks

BICO

0

Falling edge probe 1

Activation of measuring time determination with the next falling

CI: p0682

1

Falling edge probe 2

edge

 

For telegram 392, in addition, probes 3 and 6

 

2

Falling edge probe 3

 

 

 

3

Falling edge probe 4

 

 

4

Falling edge probe 5

 

 

5

Falling edge probe 6

 

 

6...7

Reserved

 

8

Rising edge probe 1

Activation of measuring time determination with the next rising edge

 

9

Rising edge probe 2

For telegram 392, in addition, probes 3 and 6

 

10

Rising edge probe 3

 

 

11

Rising edge probe 4

 

 

12

Rising edge probe 5

 

 

13

Rising edge probe 6

 

 

14...

Reserved

 

15

 

 

 

 

CU_ZSW (status word for Control Unit, CU)

See function diagram [2458]

386

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 386
Image 386
Efficient Networks S120 manual Cuzsw status word for Control Unit, CU