Basic information about the drive system 12.10 Rules for wiring with DRIVE-CLiQ

12.10.2Rules for different firmware releases

Rules for FW2.1

Only one Active Line Module can be connected to a Control Unit.

The default sampling times must not be changed.

A Double Motor Module must not be operated as a single drive.

Mixed operation of servo and vector V/f is not permitted.

The Active Line Module and the Motor Modules must be connected to separate DRIVE- CLiQ lines, both for vector and for servo.

Table 12-16 Maximum number of drives that can be controlled by a Control Unit 320

 

Servo

Vector

Number of components

1 Active Line Module +

1

Active Line Module +

 

6 Motor Modules

2

Motor Modules

 

 

(scanning frequency of current controller

 

 

250 µs /

 

 

speed controller 1000 µs)

Note:

In addition, the "Safe Standstill" function can be activated and a TM31 connected.

Rules for FW2.2

Only one Active Line Module can be connected to a Control Unit.

The default sampling times must not be changed.

A Double Motor Module must not be operated as a single drive.

Table 12-17 Maximum number of drives that can be controlled by a Control Unit 320

 

Servo

Vector V/f (=vector

 

 

without speed control

 

 

function module)

Number of

1 Active Line Module +

1

Active Line Module +

components

6 Motor Modules

4

Motor Modules

 

 

(sampling time of current

 

 

controller 250 µs)

 

 

1

Active Line Module +

 

 

6

Motor Modules

 

 

(sampling time of current

 

 

controller 400 µs)

 

Servo and vector V/f:

 

 

 

1 Active Line Module + 5 Motor Modules

 

(servo: Current controller 125 µs / speed controller

 

125 µs vector V/f:

 

 

sampling time of current controller 250 µs with max.

2 V/f drives. Sampling time of current controller 400 µs with more than 2 V/f drives)

Vector

1 Active Line Module +

2 Motor Modules (sampling time of current controller 250 µs / speed controller 1000 µs)

1 Active Line Module +

4 Motor Modules (sampling time of current controller 400 µs / speed controller 1600 µs)

510

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 510
Image 510
Efficient Networks S120 manual Rules for different firmware releases, Rules for FW2.1, Rules for FW2.2, Servo Vector