Communication PROFIBUS DP/PROFINET IO 10.1 Communications according to PROFIdrive

MSOLL_GLATT

The torque setpoint smoothed with p0045 is displayed.

AIST_GLATT

Torque utilization smoothed with p0045 is displayed.

E_DIGITAL

MT_STW

MT_n_ZS_F/MT_n_ZS_S

CU_ZSW

This process data is part of the central process data.

IAIST_GLATT

The actual current value smoothed with p0045 is displayed.

MIST_GLATT

The actual torque value smoothed with p0045 is displayed.

PIST_GLATT

The active power smoothed with p0045 is displayed.

MELD_NAMUR

Display of the NAMUR message bit bar

WARN_CODE

Display of the alarm code (see function diagram 8066)

FAULT_CODE

Display of the alarm code (see function diagram 8060)

E_STW1 (status word for INFEED)

See function diagram [8926]

Table 10-15 Description of E_STW1 (status word for E_INF)

Bit

Meaning

 

Comments

BICO

0

Ready to power-up

1

Ready to power-up

BO: r0899.0

 

 

0

Not ready to start

 

372