Extended setpoint channel 2.3 Jog

Jog

Field bus

Setpoint via PROFIBUS, for example

Via the analog inputs of the following exemplary components:

e.g. Terminal Board 30 (TB30)

e.g. Terminal Module 31 (TM31)

e.g. Terminal Module 41 (TM41)

2.3Jog

Description

This function can be selected via digital inputs or via a field bus (e.g. PROFIBUS). The setpoint is, therefore, predefined via p1058[D] and p1059[D].

When a jog signal is present, the motor is accelerated to the jog setpoint with the acceleration ramp of the ramp-function generator (referred to the maximum speed p1082; see diagram "Function chart: jog 1 and jog 2"). After the jog signal has been deselected, the motor is decelerated via the set ramp of the ramp-function generator.

CAUTION

The jog function is not PROFIdrive compatible!

6LJQDO -RJ

6LJQDO

212))

7RWDOVHWSRLQW

HIIHFWLYH U

-RJVHWSRLQW $FWLYH

Figure 2-2 Function chart: jog and OFF1