Efficient Networks S120 manual Commissioning Profibus, Interfaces and diagnostic LED

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 410
Image 410

Communication PROFIBUS DP/PROFINET IO 10.2 Communication via PROFIBUS DP

The axis separator separates the objects in the telegram as follows:

Slot 4 and 5:

Slot 7 and 8:

Slot 10 and 11: etc.

Object 1 ––> Active Infeed (A_INF) Object 2 ––> SERVO 1

Object 3 ––> SERVO 2

10.2.2Commissioning PROFIBUS

10.2.2.1General information about commissioning

Interfaces and diagnostic LED

A PROFIBUS interface with LEDs and address switches is available as standard on the Control Unit.

352),%86

LQWHUIDFH

352),%86

GLDJQRVWLFV/(''3

352),%86

DGGUHVVVZLWFKHV

Figure 10-25 Interfaces and diagnostic LED

PROFIBUS interface

The PROFIBUS interface is described in the following documentation:

410

Drive Functions

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4