Basic functions

6.5dv/dt filter plus VPL

Maximum permissible motor cable lengths:

Unshielded cables: max. 150 m

Shielded cables: max. 100 m

Other restrictions: see the Equipment Manual.

Note

If a filter cannot be parameterized (p0230 < 3), this means that a filter has not been provided for the component. In this case, the drive converter must not be operated with a sinusoidal filter.

Table 6-5

Parameter settings for sinusoidal filters

 

 

 

 

Order no.

Name

Setting

p0233

 

Power unit motor reactor

Filter inductance

p0234

 

Power unit sinusoidal filter

Filter capacitance

 

 

capacitance

 

p0290

 

Power unit overload response

Disable pulse frequency reduction

p1082

 

Maximum rotational speed

Fmax filter/pole pair number

p1800

 

Pulse frequency

Nominal pulse frequency of the filter

p1802

 

Modulator modes

Space vector modulation without

 

 

 

overmodulation

6.5dv/dt filter plus VPL

Description

The dv/dt filter plus VPL consists of two components, the dv/dt reactor and the voltage limiting network (Voltage Peak Limiter), which limits voltage peaks and returns the energy to the DC link.

The dv/dt filter plus VPL is to be used for motors for which the voltage strength of the insulation system is unknown or insufficient. Standard motors of the 1LA5, 1LA6 and 1LA8 series only require them at supply voltages > 500 V +10 %.

The dv/dt filter plus VPL limit the rate of voltage rise to values < 500 V/µs and the typical voltage peaks to the values below (with motor cable lengths of < 150 m):

<< 1000 V at Uline < 575 V

<1250 V with 660 V < Uline < 690 V

WARNING

When a dv/dt filter is used, the maximum pulse frequency of the drive converter is 2.5 kHz (chassis power units up to 250 kW at 400 V) or 4 kHz (chassis power units from 250 kW to 800 kW at 400 V). If a higher pulse frequency is set, then this could destroy the dv/dt filter.

186