Troubleshooting
Troubleshooting
Important: It is essential that all operator safety mechanisms be connected and in proper operating condition prior to mower use.
The following table lists some of the common causes of trouble. If assistance is needed, contact your Exmark Service Dealer.
Problem |
| Possible Cause |
| Corrective Action |
|
|
|
|
|
Discharge gate does not open and/or close. | 1. | Discharge gate is deformed. | 1. | Reshape the discharge gate. |
| 2. | Discharge gate is not adjusted properly. | 2. | Adjust the cable nuts and/or pivot gate. |
| 3. | Cable is disconnected at one or both ends. | 3. | Reconnect cable. |
|
|
|
|
|
Handle is too loose or tight. | 1. | Pivot bolt and nut not adjusted properly. | 1. | Adjust the bolt and nut for proper |
|
|
|
| resistance. |
|
|
|
|
|
18