Head cleaning

After long usage, tape coating or dust may adhere to the heads, causing deterioration of sound. Therefore, the parts depicted in the illustration should be cleaned reguraly. Use a cotton swab moistened with a tape head cleaning solution (such as alcohol).

Note:

1.Some cleaning cassettes on the market have strong abrasive effects and may scratch the heads. Always use cotton swabs instead of cleaning cassettes.

2.Since the use of metal tape is apt to collect more dust on the heads, the heads should be cleaned more often to enjoy the best possible sound.

CAPABILITY OF REMOTE CONTROL

 

 

 

 

 

 

 

RC-5 CODE

PLAY (

)

1853

 

 

 

FF (

)

1852

 

 

 

REW (

)

1850

 

 

 

 

 

 

 

PAUSE (

 

 

 

 

)

1848

 

 

 

 

 

 

 

 

 

 

STOP (

 

 

 

 

)

1854

 

 

 

 

 

 

 

 

REC

 

 

1855

 

 

REC MUTE

1842

 

 

COUNTER RESET

1849

 

 

 

 

DECK A

 

 

1844

 

 

 

 

DECK B

 

 

1846

 

 

 

DIRECTION (

)

1847

 

 

 

 

 

 

 

 

Cleaning the Pinch Rollers and Capstans

If the pinch roller or capstans accumulate dust, tape transport may become unstable, as a result from slippage, during recording or playback. The tape can also be damaged if it gets entangled in the capstan.

Clean these parts with a cotton swab or a soft cloth moistened with a tape head cleaning solution (such as alcohol).

Demagnetizing the Heads

The heads may become magnetized after long usage or if storongly magnetized objects are brought near them. The result is a generation of noise, loss of the high frequency range, and in extreme cases erasure of trable components on pre-recorded tapes in combination with added noise.

Thus, the heads should be demagnetized at regular intervals. (Head demagnetizers are sparately available from your dealer.)

How to Demagnetize the Tape Heads

1.Turn off the power.

2.Turn on the demagnetizer while it is at least 30 cm away from the heads. Bring the demagnetizer near the heads and slowly move it in small circles four or five times in front of each head, making sure you do not touch them.

3.Slowly move the demagnetizer away and turn it off when it is at least 30 cm away from the heads.

4.For more details, please read the User Guide provided with the demagnetizer (optional).

8

Image 13
Contents Model PMD505 User Guide Handle the power supply cord carefully Important to SafetyPrecaución Do not open the top coverImportant Safety Instructions Iii Page Table of Contents FeaturesEnglish Español FrançaisEnglish Français Names and Functions of PartsEspañol Cassette Tapes Français EnglishAutomatic Tape Selection Français Espa PlaybackÑOL Espa ÑOL Français EnglishProper Recording Level REC Mute and REC Pause ButtonSynchro Reverse Dubbing Français EspañolTape Counter AIS EnglishEspañol Franç Dolby B and C Noise Reduction SystemEnglish Français Español MaintenanceUsing the Remote Control Unit Remote ControlSpecifications TroubleshootingNon-Transferable Warranty Is a registered trademark