Husqvarna 966061101, 966062201 manual Weak Battery, Jumper Cables, To remove cables, reverse order

Page 34

OPERATION

Weak Battery

WARNING!

Lead-acid batteries generate

explosive gases. Keep sparks, flame and smoking materials away from batteries. Always wear eye protection when around batteries.

IMPORTANT INFORMATION

 

The mower is equipped with a 12-volt negative

 

grounded system. The other vehicle must also

 

be a 12-volt negative grounded system. Do not

 

use the mower to start other vehicles.

 

If “jumper cables” are used for emergency starting,

 

follow this procedure:

 

Jumper Cables

 

• Connect each end of the RED cable to the

 

POSITIVE (+) terminal on each battery, taking

 

care not to short against chassis.

 

• Connect one end of the BLACK cable to the

8011-642

NEGATIVE (-) terminal of the fully charged battery.

Jumper cable connection

 

• Connect the other end of the BLACK cable to a

 

good CHASSIS GROUND on the mower with the

 

discharged battery, away from the fuel tank and

 

battery.

 

To remove cables, reverse order

Remove BLACK cable first from chassis and then from the fully charged battery.

Remove RED cable last from both batteries.

34

Image 34
Contents Operator Manual Page Contents Page Introduction Good Service Manufacturing NumberSymbols and decals Manual Performing any Safety Instructions SafetyGeneral Operation Never take passengers Personal Safety Equipment Slope OperationChildren Safe Handling of Gasoline Safe Handling of Propane General Maintenance Risk of sparking Transport Rollover Protection System Rops Spark ArrestorsGas Engine ControlsControl Locations EngineMotion Control Levers Hour Meter Tracking KnobIgnition Switch Blade SwitchParking Brake Ignition switch RUN position Choke Control FusesCutting Height Pedals Seat Adjustment Lever Fuel Shut Off ValveRefueling Propane Model Training OperationSteering Roll Bar and Safety Belt Before StartingStarting the Engine Gasoline engines only Turn fuel shut off valve counter clockwise to open Push choke in after starting Jumper Cables Weak BatteryTo remove cables, reverse order Running Ensure that no one is near mower when engaging blade switch Operating on HillsStopping the Engine Mowing Tips Manual Transport Maintenance Maintenance For cleaning BatteryFor replacing Tire Pressures Safety SystemFuel Filter Gasoline Engines OnlyParking brake adjustment Neutral Adjustments Deck Belt Deck Belt InstallationDeck Belt Removal Belts Belt InstallationPump Belt Replacing Pump BeltCutting Blades Adjusting the Mower Deck Leveling DeckAnti-scalp Rollers Deck Lift SpringUse protective glasses when cleaning and washing CleaningRemoval and Installation Caster WheelsLubrication Schedule LubricationGeneral Front Wheel Mount Wheel and Deck ZerksCables Front Wheel BearingsHydraulic Drive Fluid ChangePurging Procedures Troubleshooting guide Problem CauseTroubleshooting guide Storage ServiceWinter Storage Wiring Diagram PZ 5426FX PZ6030CV Engine Technical DataTransmission Dimension PZ 5426FX PZ6030CV FramePZ6029FX PZ7234FX Engine PZ6029FX PZ7234FX Frame PZ6029PFX Engine FX801V LPPZ6029PFX Frame Standard Hardware Torque SpecificationsHex Head Cap Screws Metric Standard HardwareUSA requirements CE requirementsAction Service JournalDelivery Service Stamp, signAfter 10 hours Date, mtr reading Stamp, signDaily Service Hour Service Service Journal Service Journal At least once each year Action Date, mtr reading Stamp, sign Service Journal Service Journal Service Journal Page 115 254426 R1 09/14/09