Test instrumentation

 

 

Model name

 

 

Manufacturer

 

 

Serial or Firmware

 

 

Calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(No./Ver.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Date

 

 

 

 

 

 

 

 

 

 

 

 

 

Stopwatch

 

PC90

 

Time Art

 

TPST003

 

1st Apr. 2015

 

 

 

 

 

 

 

 

 

 

Power meter

 

WT1806

 

Yokogawa

 

0GAA-B04817

30th Mar. 2015

 

Power Source

61605

 

 

Chroma

 

0GAA-B05037

7th Oct. 2015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.8Measurement method used

-Measurement condition_1) Picture : no input load, 2) Sound : no input load.

-Deactivate all other network ports that are not under test.

-Ensure that the EUT does not perform a main function and wait for 20 minutes, So that the EUT able to go into the networked mode.

-The EUT standby mode power consumption was monitored for a further period of 5 minutes.

The variation in power consumption over this period is 5%, so the maximum reading of NTW standby mode power as measured by the power analyzeris recorded as the test result

1.9 Set-up and circuit for electrical testing ( Insert the picture or diagram of the test configuration )

2. Off mode

2.1 Test result

 

 

Test date

 

 

 

4th Jan. 2016

 

 

Power Consumption (W)

 

 

0.0

 

 

 

 

 

 

 

(rounded to the 1st decimal place)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2 Test parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parameters

 

 

Actual

 

Limit

 

parameters

Actual

 

Limit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature (

)

 

26.0

 

23±5

 

Test voltage (V)

230

 

230±2.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test frequency (Hz)

 

 

50

 

50±0.5

 

Total harmonic distortion

1.42

 

2

 

 

 

 

 

 

 

 

 

 

 

(%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crest factor

 

1.40

 

1.34~1.49

 

-

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.3 Description of how the appliance mode was selected or programmed Standby mode was selected by turning off by remote server