1. Manuals
  2. Brands
  3. TV and Video
  4. Professional LFD Displays
  5. Samsung
  6. TV and Video
  7. Professional LFD Displays

Samsung QB65H Control Codes, Viewing control state (Get control command), Controlling (Set control command), Command, No, Command type, Command, Value range

LH43DBJPLGC/CH, LH43DBJPLGC/EN, LH43DBJPLGC/UE, LH43DBJPLGC/XV, LH49DBJPLGC/CH, LH49DBJPLGC/EN, LH49DBJPLGC/XV, LH49QMHPLGC/CH, LH49QMHPLGC/EN, LH49QMHPLGC/UE, LH55QHHPLGC/EN, LH55QHHPLGC/XV, LH55QMHPLGC/CH, LH55QMHPLGC/EN, LH55QMHPLGC/NG, LH65QBHPLGC/CH, LH65QBHPLGC/EN, LH65QBHPLGC/XV, LH65QHHPLGC/EN, LH65QMHPLGC/CH, LH65QMHPLGC/EN, LH65QMHPLGC/UE, LH65QMHPLGC/XV, LH75QBHPLGC/CH, LH75QBHPLGC/EN, LH75QBHPLGC/UE

1 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 146
Download on canonical page 146 pages, 4.07 Mb

Control Codes

Viewing control state (Get control command)

Header

Command

ID

Data length

Checksum

 

 

 

 

 

0xAA

Command

 

0

 

 

type

 

 

 

 

 

 

 

 

Controlling (Set control command)

Header

Command

ID

Data length

Data

Checksum

 

 

 

 

 

 

0xAA

Command

 

1

Value

 

 

type

 

 

 

 

 

 

 

 

 

 

Command

No.

Command type

Command

Value range

 

 

 

 

1

Power control

0x11

0~1

 

 

 

 

2

Volume control

0x12

0~100

 

 

 

 

3

Input source control

0x14

-

 

 

 

 

4

Screen size control

0x19

0~255

 

 

 

 

5

Video wall mode control

0x5C

0~1

 

 

 

 

6

Safety Lock

0x5D

0~1

 

 

 

 

7

Video Wall On

0x84

0~1

 

 

 

 

8

Video Wall User Control

0x89

-

 

 

 

 

•• All communications take place in hexadecimals. The checksum is calculated by adding up all values except the header. If a checksum adds up to be more than 2 digits as shown below (11+FF+01+01=112), the first digit is removed.

E.g. Power On & ID=0

Header

Command

ID

Data length

Data 1

Checksum

 

 

 

 

 

 

0xAA

0x11

 

1

"Power"

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

Command

ID

Data length

Data 1

12

 

 

 

 

 

 

0xAA

0x11

 

1

1

 

•• To control all devices connected by a serial cable simultaneously irrespective of IDs, set the ID as "0xFE" and transmit commands. Commands will be executed by each device but ACK will not respond.

34

MENU

Models

Contents