Best WP29M manuals
Kitchen Appliance > Ventilation Hood
When we buy new device such as Best WP29M we often through away most of the documentation but the warranty.
Very often issues with Best WP29M begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Ventilation Hood Best WP29M is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Ventilation Hood on our side using links below.
Best WP29M Installation Instructions
36 pages 8.47 Mb
WP29M SERIESREAD AND SAVE THESE INSTRUCTIONS 2 WARNING WARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: CAUTION 3 - WP29M SERIES RANGE HOOD SYSTEM - INTERIOR BLOWERS4 - WP29M SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLOWERSModel EB6 (600 cfm) or EB9(900 cfm) exterior blower Model EB12 (1200 cfm) or EB15 (1500 cfm) exterior blower Model 437 (High capacity roof cap) 5 1. SELECT BLOWER OPTION AND INSTALLATION TYPE1.2 DUCTED INSTALLATION 1.1 NON-DUCTED INSTALLATIONMODEL P6 SINGLE INTERIOR BLOWER TYPICAL DUCTWORK MODEL P12 DUAL INTERIOR BLOWER TYPICAL DUCTWORK MODEL EB6, EB9, EB12 OR EB15 EXTERIOR BLOWER TYPICAL DUCTWORK MODEL ILB3, ILB6, ILB9 OR ILB11 IN-LINE BLOWER TYPICAL DUCTWORK 6 3. PREPARE THE INSTALLATION2. MEASURE INSTALLATIONMINIMUM AND MAXIMUM DISTANCE OVER COOKTOP 7 6. INSTALL WOOD MOUNTING STRIP4. REMOVE THE FILTERS AND THE GREASE DRIP RAIL(S) 5. REMOVE THE PAN 7. INSTALL THE FLUE AND/OR THE FLAT TOP COVER7.1 DUCTED INSTALLATION:A) OPTIONAL DECORATIVE FLUE AEWP SERIES B) OPTIONAL FLAT TOP COVER ADPWP SERIES 7.2 NON-DUCTED INSTALLATION: NON-DUCT KIT FLUE ANKWP SERIES 8 11.INSTALL THE ROUGH-IN PLATE T O THE HOOD 11.1 ALL INSTALLATIONS: 11.2 DUCTED INSTALLATIONSONLY:Model 423, 424, 427 453, or 454 9. SELECT BLOWER OPTION 10.INSTALL TRANSITION TO ROUGH-IN PLA TE 8. INSTALL THE HOODInstall the Rough-in Plate. Hold the hood until it is completely secured to the wood mounting strip. 12.CONNECT THE WIRING 9 13.INSTALL THE BLOWER Do not plug the two cords into each other. Remove protective plastic film covering Evolutionary hybrid baffle filters before installing them. 14.REINSTALL THE PAN 15.REINSTALL GREASE DRIP RAIL(S) AND BAFFLE FILTERS15.1 DUCTED INSTALLATION: 15.2 NON-DUCTED INSTALLATION: 10 16.LIGHT BULBS REPLACEMENT17.USE AND CAREEvolutionary Hybrid Baffle Filters Grease Drip Rail Blower Cleaning Hood Cleaning 11 18.OPERATIONBlower HEAT SENTRYCooktop Lighting (Halogen) WARRANTY 12 SERVICE PARTSWP29XX4 WP29XX7 SAME PARTNUMBERS, EXCEPT FOR ITEM 11 (SEE BELOW) CONUE UNIQUEMENT POUR LA CUISSON DOMESTIQUE GUIDE DINSTALLATION LIRE ET CONSERVER CES INSTRUCTIONS 13 SRIE WP29M25 SERIE WP29M26 ADVERTENCIA ADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIO DE GRASA EN LA SUPERFICIE DE LA ESTUFA: PRECAUCIN 27 - CAMPANAS DE COCINA DE LA SERIE WP29M - VENTILADORES INTERIORESModelo 415 (Codo ajustable redondo de 7pulg.)Modelo 634 o 644 (Capuchn para tejado) 28 - CAMPANAS DE COCINA DE LA SERIE WP29M - VENTILADORES EN LNEA Y EXTERIORESModelo 421 (Dispositivo de cierre redondo, vertical y en lnea de 10) Modelo 410 (Tubo redondo de 10, secciones de 2 pies) Modelo 418 Codo ajustable redondo de 10 (opcional) 29 1. SELECCIN DEL TIPO DE VENTILADOR E INSTALACIN1.2 I 1.1 IINSTALACIN HABITUAL CON EL VENTILADOR SIMPLE P6 INSTALACIN HABITUAL CON EL VENTILADOR DOBLE P12 INSTALACIN HABITUAL CON LOS VENTILADORES EXTERIORES EB6, EB9, EB12 O EB15 INSTALACIN HABITUAL CON LOS VENTILADORES EN LNEA ILB3, ILB6, ILB9 O ILB11 30 3. PREPARACIN DE LA INSTALACIN2. MEDIDASSe aconseja llevar anteojos y guantes de seguridad al instalar, reparar o limpiar el aparato. DISTANCIA MNIMA Y MXIMA ENTRE LA CAMPANA Y LA SUPERFICIE DE COCCIN 31 4. DESMONTAJE DE LOS FILTROS Y DEL CANAL5. DESMONTAJE DE LA PLACA 6. INSTALACIN DE LA REGLETA DE MONTAJE 7. INSTALACIN DE LA CHIMENEA Y/O DE LA PLACA DE RECUBRIMIENTO7.1 INSTALACIN CON TUBOS:A) CHIMENEA DECORATIVA OPCIONAL, SERIE AEWP B) PLACA DE RECUBRIMIENTO OPCIONAL, SERIE ADPWP 7.2 INSTALACIN SIN TUBOS: CHIMENEA DEL JUEGO PARA INSTALACINSIN TUBOS, SERIE ANKWP 32 11. INSTALACIN DE LA PLACA DEL VENTILADOR EN LA CAMPANA 11.1 TODAS LAS INSTALACIONES: 11.2 INSTALACINCON TUBOS SOLAMENTE:Modelos 423, 424, 427, 453 o 454 9. SELECCIONE LA OPCIN DE VENTILADOR 10 .INSTAL. DEL CAMBIO DE SECCIN EN LA PLACA DEL VENTILADOR 8. INSTALACIN DE LA CAMPANAInstalacin de la placa del ventilador en la campana Sujete la campana hasta que est totalmente asentada contra la regleta de montaje. 12.CONEXIN DEL CABLEADO 33 13.INSTALACIN DEL VENTILADOR No enchufe los dos cables uno con otro. 14.REINSTALACIN DE LA PLACA 15.REINSTALACIN DE LOS FILTROS Y DEL (O DE LOS) CANAL(ES)15.1 INSTALACINCON TUBOS: 15.2 INSTALACINSIN TUBOS: 34 16.SUSTITUCIN DE LAS BOMBILLAS17.USO Y CUIDADOFiltros hbridos Evolutionary Limpieza del canal Limpieza del ventilador Limpieza de la campana 18.FUNCIONAMIENTOVentilador Termostato Heat Sentry Interruptor de luces halgenas 35 GARANTA36 PIEZASMODELO WP29XX4 MODELO WP29XX7LOS NMEROS DE LAS PIEZAS SON LOS MISMOS EXCEPTUANDOLA PIEZA 11 (VASE ABAJO).
Also you can find more Best manuals or manuals for other Kitchen Appliance.