Carrier 58MCA manuals
Household Appliance > Furnace
When we buy new device such as Carrier 58MCA we often through away most of the documentation but the warranty.
Very often issues with Carrier 58MCA begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Furnace Carrier 58MCA is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Furnace on our side using links below.
12 pages 322.11 Kb
Also you can find more Carrier manuals or manuals for other Household Appliance.
Carrier 58MCA Instruction Manual
16 pages 289.5 Kb
58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Service and Maintenance InstructionsFig. 1Multipoise Furnace in Upflow Orientation For Sizes 040140, Series 131ama2 Fig. 2Multipoise Orientations 3 Fig. 3Bottom Filter Arrangement Fig. 4Filter Installed for Side Inlet 4 Table 1Speed SelectorFig. 5Burner Box Assembly 5 Fig. 6Cleaning Inlet Openings of Primary Heat ExchangersFig. 7Combustion-Air Intake Housing Gasket Repair Fig. 8Furnace Pressure and Drain Tubing Diagram LEVEL (0") TO NOTE: 322593-101 REV. A 1/2" MAX HORIZONTAL UPFLOW OR DOWNFLOW 6 INSTALLATIONTO Tube location when used in DOWNFLOW application Tube location when used on HORIZONTAL - RIGHT applicationCondensate Trap; Factory Installed in Blower Shelf Condensate Trap on LEFT Side Optional Condensate Trap on RIGHT Side Condensate Trap on LEFT Side Tube location when used in UPFLOW application Tube location when used on HORIZONTAL - LEFT application(Blower access panel removed) 7 Fig. 9Burner Flame Fig. 10Gasket on Collector Box 8 Fig. 12Field Wiring A96415Fig. 11Hot Surface Ignitor Location and Burner Assembly 9 Fig. 13Control Center Fig. 16Wiring Diagram NOTE #4 10. BLOWER-OFF DELAY, GAS HEATING 90, 135, 180 OR 225 SECONDS, COOLING OR 9. BLOWER-ON DELAY, GAS HEATING 60 SECONDS, COOLING OR HEAT PUMP 2 SECONDS. 8. YELLOW LEAD NOT ON ALL MOTORS. 7. REPLACE ONLY WITH A 3 AMP FUSE. 2. INDUCER (IDM) AND BLOWE R (BLWM) MOTORS CONTAIN INTERNAL 1. IF ANY OF THE ORIGINAL EQUIPMENT WIRE IS REPLACED USE WIRE RATED FOR 105C. NOTES:TO 115VAC FIELD DISCONNECT GVR HSIR IDR BL WR 225 SEC 180 SEC 135 SEC 90 SEC 12 PCBHI/LO RELAY LEGEND SCHEMATIC DIAGRAM (NATURAL GAS & PROPANE) 322854-101 REV. CFLAME. 6. FACTORY CONNECTED WHEN LGPS NOT USED. Fig. 17Service Label A96263 13 SERVICECOMPONENT TEST LED CODE STATUS 14 Troubleshooting Guide16 SERVICE TRAINING
Also you can find more Carrier manuals or manuals for other Household Appliance.